Accurate device to measure CO2 concentration reliably.

Accurate measurement of VOC concentration and odors.

Digital humidity and temperature sensor.

2 outputs for easy connection: analog (0-10V) and digital (PWM).

Can be adapted to different markets and applications.

Compact design, simple to install, ready to use.

No maintenance.

Description
Characteristics
Schematic
Gallery
Documents

S-CO2, a reliable and accurate device that enables systems to optimize indoor air quality

Indoor air quality can generally be assessed by measuring the concentration of carbon dioxide, known to be representative of indoor air conditions. The S-CO2 is useful in many places (such as schools, office buildings, and private homes) where the concentration of CO2 can vary with the occupancy and use of the rooms. Its technologies ensure long-term stability and performance: the S-CO2 is pre-calibrated to measure, in real time, indoor CO2 concentrations from 0 to 2000 ppm, and it delivers both analog (0-10 V) and digital (PWM) output signals. Thanks to its dual-beam measurement technology, the S-CO2 can be placed in any room, at any time, whatever the installed system. The Aereco CO2 sensor integrates the NDIR technology, a selective auto-calibrated technology that allows a good assessment of the indoor air quality.

S-VOC, a smart sensor for holistic assessment of indoor air quality 

The S-VOC is designed to accurately and reliably assess the level of volatile organic compounds (VOCs) typically associated with cigarette smoke, cooking smells and other pollutants. Using the MOS technology, the S-VOC measures the concentration of VOC and odours at a real time and evaluates the CO2 level of the room (see graph below). Its output signal reports values from 0 to 2000 on a “ppm CO2 equivalent” IAQ scale. This output signal is available simultaneously in two forms: analog (0-10V) and digital (PWM).

S-RH/T, a versatile unit that measures humidity and temperature

The S-RH/T is designed for applications such as demand-controlled ventilation and air conditioning where accurate measurements, excellent long-term stability, and maintenance free-operation are absolute musts. The temperature and humidity measurements are available simultaneously to optimize their contribution to comfort and health.
 

    S-CO2 S-VOC S-RH/T
Standard code   CAP1159 CAP1160 CAP1161
Measurement principle   Non-Dispersive Infrared Technology (NDIR), Dual-Source Infrared System Micro-machined metal oxide semiconductor (MOS) technology Capacitive humidity sensor Band gap temperature sensor
Working range   0…2 000 ppm CO2 0…2 000 ppm CO2 eq 0°C + 50°C 0% – 100% Relative Humidity
Accuracy at 25°C and 1 013 mbar ppm  ± (60 ppm +2 % of measured value in a [0 ppm; 2000 ppm] range)
Response time s < 195 s
Temperature dependence CO/ °C typ. 2 ppm CO2 / °C (0…50°C)
Long-term stability ppm / year typ. 20 ppm / year
Precision RH   typical +/-2,5 %, max +/-3,5 % RH at 25°C in 20 % -80 % range
Accuracy of temperature   max +/-0,6°C in [5°C ; 50°C] range, typical 0,5°C
Measurement reporting interval s 60 s 60 s 60 s
Supply voltage VDC 12 VDC +/- 10 % 12 VDC +/- 10 % 12 VDC +/- 10 %
Average power consumption A 120 mA (reading), 10 mA (base). 40 mA 15 mA
Max. peak current A 1 A (use for fuse sizing) 1 A (use for fuse sizing) 1 A (use for fuse sizing)
Enclosure protection   IP 20 IP 20 IP 20
Storage conditions   -40…60°C 5…95 % RH (without condensating) 85…110 kPa -25…50°C 5…95 % RH (without condensation) 85…110 kPa 10…50°C 0…60 % RH
Working conditions   -40…60°C 5…95 % RH (without condensating) 85…110 kPa 0…50°C 5…95 % RH (without condensation) 85…110 kPa
PWM digital output        
Output data ppm 0 % = 0 ppm ; 100 % = 2 000 ppm 0 to 100 % 0 % = 0 ppm CO2 eq ; 100 % = 2 000 ppm CO2 eq 0 to 100 % 0 % = 0 % RH – 100 % = 100 % RH 0 % = 0°C – 100 % = + 50°C
Voltage VDC 12 VDC +/- 10 % 12 VDC +/- 10 % 12 VDC +/- 10 %
Frequency KHz 1 KHz 1 KHz 1 KHz
0-10 V analog outpout        
Output data   0 to 10 V. 0 V = 0 ppm ; 10 V = 2 000 ppm 0 to 10 V 0 V = 0 ppm CO2 eq ; 10 V = 2 000 ppm CO2 eq 0 to 10 V 0V = 0 % RH – 10 V = 100 % RH 0V = 0°C – 10 V = + 50°C 
Voltage V 0 to 10 V 0 to 10 V 0 to 10 V
Required impedence Ω >1MΩ >1MΩ >1MΩ
Characteristics        
Weight g 80.5 g 80.5 g 80.5 g
Colour   white white white
Material   ABS ABS ABS

SENSORS / DIMENSIONS IN MM

S-Serie

Indoor air quality sensors – Booklet – CAT623GB_v2

Compatible ventilation systems: