FLUSH-MOUNTED DEMAND CONTROLLED EXHAUST UNIT FOR MEV
The concealed humidity-controlled extract unit with integrated filter to
preserve the durability of installations.
The BXC-EF combines the BXC-E range with a grease filter to prevent clogging and increase durability. To preserve the aesthetics of the diffuser, the filter has been integrated into the design using an aesthetic perforated plate. The recessed casing of the BXC-E has been kept to minimise the visual clutter of the diffuser.
Flush-mounted exhaust unit : discreet and non-intrusive.
Humidity sensitive switch versions : modulates the airflow according to the various needs of the dwelling.
Silent working : silent auxiliary airflow activation
Battery indicator : buzzer to indicate low battery level
Easy to maintain : removable shutter case and front cover for easy cleaning
Description
Characteristics
Schematic
Accessories
Videos
Airflow ‘+’
Based on the same principle as the BXC-E range, this new unit uses a humidity sensor to adjust the opening of the unit and the air renewal in each room. Thanks to optimised ventilation, the BXC-E range promises immediate energy savings. If required, an additional airflow can also be activated by switch.
Adjustment of flow and installations compliance
The integrated pressure plug measures the pressure directly at the extract unit to check that installation complies with regulations. In the event of a particular configuration or insufficient pressure, the adjustment flap can be adjusted to increase the flow cross-section (6 positions with an interval of 10m3 /h) and thus ensure compliance with regulatory requirements.
Design grease filter for the kitchen/dining room
The grease filter is used to filter grease and large dust particles. Suitable for use in kitchens to prevent clogging and preserve the durability of installations.
Flush-mounted exhaust unit
BXC-EC h
BXC-EC h
BXC-EC h
BXC-EC hi
BXC-EC f
Standard code (other versions available, please contact us) ø100
BXE2070
BXE2080
BXE2079
BXE2075
BXE2072
Angled version ø100
BXE2069
–
–
BXE2076
–
Airflow characteristics
Humidity sensitive
■
■
■
■
–
Boost airflow
■
■
■
■
–
Boost airflow activated by switch
–
–
–
■
Boost airflow activated by presence detection
–
–
–
–
–
Airflow @ 100 Pa (min.-max.) (1) (2)
m3/h
12-80
12-60
12-45
12-80
12
Airflow ’+’ – maximum available airflow @ 100 Pa (3)
12 VAC supply with specific transformer (ref. CAL261)
–
–
–
⊗
–
230 VAC supply with specific transformer (ref. CAL1228)
–
–
–
⊗
–
Characteristics
Colour
white RAL9003
white RAL9003
white RAL9003
white RAL9003
white RAL9003
Material (main)
PS / ABS
PS / ABS
PS / ABS
PS / ABS
PS / ABS
Installation
Round duct compatibility with integrated spigot
mm
ø100
ø100
ø100
ø100
ø100
Round duct compatibility with integrated spigot with integrated 90° elbow ferrule ø100 (4)
mm
■
–
–
■
–
Round duct compatibility with accessory spigot (5)
mm
ø125
ø125
ø125
ø125
ø125
Round duct compatibility with 85343AL accessories
mm
ø80
ø80
ø80
ø80
ø80
Other functions
Pressure plug
■
■
■
■
■
Fault indicator thanks to a built-in pressure sensor
–
–
–
–
–
■ : standard / included ⊗ : compatible
Note: airflow given for a ø100 duct
(1) Default setting.
(2) Tolerance : 12m3/h +/- 3 , 80m3/h +/- 10.
(3) Airflow ‘+’: the airflow can be increased from +10 m3/h to +50 m3/h (6 positions available). This function can be used to adapt to lower pressure or to specific regulations imposing higher airflows. Standard is position 0 (minimum airflow = 12 m3/h @ 100 Pa).
(4) Delivered in specific versions.
(5) Delivered in specific versions or available as accessory (ref. AEA317).
Other versions available, please contact us.
AIRFLOW / DIMENSIONS IN MM
IMAGE
CODE
DESIGNATION
CAF
CAF Stops the propagation of fire cold smokes through ventilation ducts
CAL261
CAL261 Supply device 12 VAC / 3 VDC (mandatory for BXC connected to 12 VAC supply)
CAL1228
CAL1228 Supply device 230 VAC / 3 VDC (mandatory for BXC connected to 230 VAC supply)
33007AL
33007AL Trident plastic sleeve ø125 mm – L 125 mm
85343AL
85343AL Trident plastic sleeve ø125 mm – ø80 mm – L 125 mm
The TDA exhaust units directly adjust the extracted airflow to the level of human presence detected in the room. The airflow level in “presence” mode can be adjusted at every moment according to the usual number of occupants in the room (1 to 4 persons per vent).
Humidity sensitive exhaust unit for natural and hybrid ventilation
By adjusting the airflow to the ambient relative humidity rate, the GHN humidity sensitive exhaust unit is the perfect solution for the natural ventilation of wet rooms. Directly replacing the old exhaust unit without modification of the hole, it fits perfectly into the environment of bathroom, toilets and kitchen. Its robust and reliable humidity sensitive sensor ensures optimum performance at all the times, with remarkable longevity.
Humidity sensitive exhaust unit for natural and hybrid ventilation
Specially adapted to work at low pressure, the GBP humidity sensitive exhaust unit is an ideal solution for the renovation of ventilation ductworks initially operating in natural ventilation. The GBP exhaust unit is available in several versions activated by a humidity sensitive sensor or by a pull cord, for implementation on shunt or individual air ducts.
The BXC2 exhaust unit incorporates all the functions one could request from an air exhaust unit. With various activation modes such as humidity, presence, CO2 and VOC for example, the BXC2 exhaust unit automatically adjusts the level of ventilation according to occupants’ needs in all situations, all rooms.